Super User
The CFL SIMF, Cable Fault Secondary Impulse Filter from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately.
Cable Fault Secondary Impulse Filter CFL SIMF is mainly used for high resistance and flashing fault test for power cable with the voltage below 10kV, and for fault location with Secondary Impulse with the conjunction of Pre-locator and HV surge generator. Latest fault locating technique for high resistance and flashing faults is Secondary Impulse Method (SIM). This method offers highly reliable results for faults on any type of power cable. It converts the faults to low resistance nature by creating an arc across the fault.
It is a passive filter having its own output power source. It uses the energy of the surge generator to create an arc at the fault point. A high voltage switch incorporated in the output circuit facilitates selection of SIM or ICM mode.
The new generation CFL AG2 Cable Fault Audio Generator from SCOPE is the ultimate solution for locating the underground cable lay in minimum time. It uses advanced technologies for auto impedance matching, and stabilised frequency which helps even an unskilled operator to locate the cable accurately.
CFL AG2 portable Audio Generator to locate the exact route of the underground cable in conjunction with Pin Pointer cum Rote Tracer i.e., CFL PP Series. This configuration is also used for depth determination of the cable and pinpointing of low resistance faults. Various modes of operation combined with advanced features offer users the most effective solution for the job.
Features
- Compact, Lightweight and Rugged
- Operation via User Friendly Interface
- Variable output power up to 20 Watt
- Automatic load matching
- Works eff ectively with high impedance loads
- Quartz Stabilised Frequency
- Continuous or Pulsed signal injection
- Over current protection
- Water resistant and dust proof design
Specifications
Parameters | CFL AG2 |
Output Power | 20W Maxiumum |
Maxiumum Output Current | 2.8A±20% |
Frequency | 1KHz sine wave |
Output Voltage | 4-7V/15-25V/30-40V/60-70V/90-100V/150-170V/200-230V |
Display | Analog Meter for Output Current |
Input Power Supply | AC 230V ±10%, 50Hz ±10% |
Protection | Over Current / Load |
Environmental (Operation) | 0°C to 50°C, 95% RH (Non-Condensing) |
Environmental (Storage) | -10°C to 60°C, up to 98% RH (Non-Condensing) |
Dimension | 275mm x 255mm x 130mm |
Weight | 4kg |
Underground cable faults cannot be avoided due to many factors such as road widening, infrastructure improvement, digging carried out for repairs of other underground utilities etc.
The new generation CFL PL4 Cable Fault Prelocator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately.
CFL PL4 portable Prelocator is used for identification of fault types in underground cables and the distance of fault. These products are designed to fi nd out various types of faults in the cable such as Open Circuit, Short Circuit, Splice in Cable, High Resistance, Moisture Ingress, etc. Various modes of operation combined with advanced features off ers user the most effective solution for the job.
Features
- User friendly operation
- Wide measurement range up to 64km
- Highest measurement accuracy of ±1% of selected range
- High speed sampling of 200MHz
- Automatic Cable End detection
- Automatic Fault Point detection
- Zoom function for detailed analysis of the waveform
- Asynchronous interference & noise suppression
- Adjustable Gain and Balance
- Inbuilt memory to store 300 waveforms with USB connectivity
- "Print-screen" function to save image in JPG
- PC Software for waveform analysis and report preparation
- High resolution 8” Colour Touchscreen display
- Mains as well as Inbuilt Rechargeable Battery operated
- Housed in weather proof molded case
Specifications
Parameters | CFL PL4 |
Modes of Operation |
TDR SIM / MIM / ARC (Up to 8 Fault Traces) ICM/ICE Voltage Decay |
Sampling Rate | 200 MHz |
Measurement Range | Up to 64 km |
Measurement Accuracy | ±1% |
Best Resolution | 1m |
Pulse Amplitude (OCV) | 30V |
Pulse Width | 40nS to 10µS |
Output Impedance | 5Ω to 87Ω |
Velocity of Propagation (V) | 90 - 300 m/µs |
Memory | 300 Waveforms |
Connectivity | USB, Direct Download to Pen drive |
Display | 8” Colour Touchscreen LCD |
Battery | Rechargeable Lithium Ion, Suitable for 8 hour operation |
Power Supply | 90V to 264V AC, 47 to 63 Hz, Single Phase |
Environmental (Operation) | -10°C to +50°C, up to 95% RH (Non-Condensing) |
Environmental (Storage) | -20°C to 70°C, up to 98% RH (Non-Condensing) |
Dimension | 339mm x 295mm x 152mm |
Weight | 4.5 kg |
HISAC Ultima – new generation Circuit Breaker Dynamic Test Set from SCOPE …. The ultimate solution for testing Circuit Breakers of all types. HISAC Ultima is the most complete analyser for checking the dynamic performance of CBs in live EHV switchyards upto 765 kV.
HISAC Ultima can carry out Dynamic Contact Resistance Measurement on SIX breaks of THREE poles in one operation thereby significantly reducing stress on CB & testing downtime.
It offers flexibility to create pre-programmed Test Plans including all test settings for all types of circuit breakers available in a switchyard that can simply be recalled at the time of actual testing. This saves you from doing all settings in switchyards.
The Analysis software offers a range of utilities which enables effective Condition Monitoring of CB by comparing present test data with previous signatures and predicting future performance.
Features
- Tests all types of circuit breakers - LV, HV & EHV for all critical performance parameters of all the poles / breaks in a single shot.
- Measures Main/PIR contact timings, bounce, non simultaneity of contacts and auxiliary contact timings.
- Analyses contact travel characteristics for speed, insertion, contact gap, over-travel and rebound with suitable transducer and mounting fixture.
- Records trip and close coil current characteristics.
- Registers the signature of Dynamic Contact Resistance of main and arcing contacts, of all the 6 breaks simultaneously.
- Displays settings, graphical and tabulated test results.
- Prints test report in graphical format with test header and calculation footer, on external printer(not supplied).
- Incorporates powerful and practical Windows™ based Test Manager Software to control & operate instrument; view, analyze and handle graphical test data on a laptop at high resolution.
- Selects pre-programmed setup parameters and pass/fail limits through software.
- Connects to CB with wear resistant test leads of sufficient length, having quick-fit connectors, suitable for EHV circuit breakers.
- Moves easily within switchyard as the set can be mounted on a specially designed Trolley having large wheels & mains supply distribution board.
- Travel – For evaluating travel characteristics of operating mechanisms, SCOPE offers rotary and linear resistive travel transducers with universal / specially designed fixtures to suit variety of CBs available.
- DCRM module captures dynamic variation in contact resistance of main & arcing contacts during breaker operation.
- Each DCRM module has in built independent isolated, rechargeable battery based 100A DC source.
- The result is plotted in graphical form on the software screen, which can be further analysed for finding parameters such as contact gap, total insertion, arcing tip insertion, main and arcing contact resistance values etc.
- Additional optional modules are available to measure PIR value and for monitoring Station DC (Coil voltage), Motor current or other static parameters through configurable Analog channels.
- Type Tested as per IEC 60068, IEC 61326 & IEC 61010-1. CE marked
- Supplied with suitable Test Leads & aluminium transport cases for instruments.
- Travel Transducer and fixture as per order based on make, type & rating of CB.
Specifications
Parameter | HISAC Ultima |
Trigger Options | O, C, C-O, O-C, O-C-O |
Timing Channel | 24 : 4 Main + 4 PIR per pole, 3 poles Simultaneously |
Auxiliary Contact Timing Channel | 8 : 4 dry + 4 wet Expandable up to 6 Dry + 6 Wet |
Best Time Resolution | 50μS |
Coil Current Channel | 3 : Trip / Close coil current optionally expandable up to 6 |
Travel Channel | 3 : Travel characteristic optionally expandable up to 6 |
Analog Channel for DCRM Input (Optional) | 1 / 2 / 3 / 6 – as per DCRM modules selected |
DCRM Resistance Range & Current (Optional) | 1000 / 2000 / 4000 / 8000 μΩ Selectable, Current 100A DC |
Static Contact Resistance (CRM) Channel | As per DCRM modules selected |
CRM Resistance Range | 1000 / 2000 / 4000 / 8000 μΩ Selectable |
Configurable Analog Channel (Optional) | Up to 6: For inputs of station battery voltage, PIR value etc. |
PIR value Measurement (Optional) | 0-5000Ω with the resolution of 1Ω |
Sampling Speed | 1 / 2 / 5 / 10 / 20 kC Selectable |
Display | Display of laptop |
Operation | Interactive menu through laptop |
PC Connectivity | Ethernet |
Printer | External through laptop |
Memory | Memory of laptop |
Dimensions | Analyser - 500 x 270 x 300 mm, DCRM Rack - 500 x 270 x 250 mm |
Instrument Weight | Analyser - 12 kg DCRM Rack-18 Kg(3 DCRM modules per Rack) |
Power | 230 V AC ± 15% , 50Hz ± 10% |
SCOT series of CB Time Interval Meters from SCOPE are compact and reliable instruments to measure operating time of all types of HV/EHV circuit breakers under charged swichyard conditions up to 400kV.
SCOT M3K measures and displays CLOSE, OPEN and CLOSE-OPEN time of main contacts of 3 poles connected end to end, simultaneously.
Features
- Inbuilt clock to tag date and time of test to the readings
- 4 line 20 character backlit LCD display for menu and results
- Inbuilt memory to hold results of last fi fty tests
- Easy to use menu driven user interface for operating
- Diagnostics for instrument condition and calibration watch
- Select the operation and mode to be performed e.g. Close, Open or CLOSE-OPEN
- Operation times of all three poles are measured and displayed simultaneously on the display
- Test results can be stored and downloaded to a PC using SCOPE’s CDATA software
Specifications
Parameters | SCOT M3K |
Channels | 3 |
Breaker Control | Solid state contacts rated 300V / 30A for breaker operation |
Output | 4 line 20 character backlit LCD RS 232C port for downloading data to PC |
Range | 999ms maximum |
Resolution | 1ms |
Measuring Accuracy | Value ± 0.05% ± 1 digit |
Test Leads | Set of 15m, wear resistant Test Cables |
Environment | 0° to 50° C, 95% RH (Non-condensing) |
Power | 230V AC ± 15%, 50Hz ± 10%, 25 VA |
Dimensions | 430 x 345 x 160 mm |
Instrument Weight | 4 kg |
SCOT Series of CB Time Interval Meter from SCOPE are compact and reliable instruments to measure operating time of all types of HV/EHV circuit breakers under charged switchyard conditions up to 400kV.
SCOT MXP measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time in various configurations. The MXP has a special mode to measure Pre-Insertion Resistor (PIR) closing time
Features
- Select the operation and mode to be performed e.g. CLOSE, OPEN or CLOSE-OPEN
- Operating time of all three poles are measured and displayed simultaneously on the display
- Test results can be stored and downloaded to a PC using SCOPE’s CDATA software
- Inbuilt clock to tag date and time of test to the readings
- 4 line 20 character backlit LCD display for menu and results
- Inbuilt memory to hold results of last 50 tests
- Easy to use menu driven user interface for operation
- Diagnostics for instrument condition and calibration watch
- Inbuilt thermal printer for printing results
Specifications
Parameters | SCOT MXP |
Channels | Maximum eight in PIR mode |
Breaker Control | Solid state contacts rated 300V / 30A for breaker operation |
Output | 4 line 20 character backlit LCD RS 232C port for downloading data to PC |
Printer | Inbuilt thermal printer, 55mm wide roll |
Range | 999ms maximum |
Resolution | 1ms |
Measuring Accuracy | Value ± 0.05% ± 1 digit |
Test Leads | Set of 15m, wear resistant test cable |
Environment | 0° to 50° C, 95% RH (Non-condensing) |
Power | 230V AC ± 15%, 50Hz ± 10%, 25 VA |
Dimensions | 430 x 345 x 160 mm |
Instrument Weight | 6kg |
SCOPE proudly intoduces new version of Calibration Standart SCALE TCV, specially designed to check calibration of SCOT and HISAC series instruments of SCOPE. Highly stable and precise signals of SCALE TCV are applied to SCOT and HISAC series instruments for calibration. SCALE TCV is calibrated from acceredited calibration laboratory and is provided with calibration certificate having traceability to national standards.
Features
- Simple, lightweight, portable
- Linear ramp signal generation for calibration of Trael and Velocity
- Highly stable current source for calibration of Current channels
- Contacts having precise close and open time for calibration of Timing channels
- Calibration port for calibration os SCALE TCV from external Standard
- Specially designed to calibrate SCOPE make SCOT and HISAC series products
Specifications
Technical Specifications
Sr. No. | Parameter | Standard Value | Sr. No. | Parameter | Standard Value |
1 | Open Time (Main) | 50 mSec | 5 | Current | 1 A |
2 | Close Time (Main) | 100 mSec | 6 | Ramp Voltage | 4 V |
3 | Open Time (Auxiliary) | 30 mSec | 7 | Open Ramp Time | 75 mSec |
4 | Close Time (Auxiliary) | 75 mSec | 8 | Close Ramp Time | 150 mSec |
General Specification
- Weight - Approx 3 kg
- Dimensions - 225mm x 150mm X 85 mm
- Power supply - 230 V AC + 15%, 50 Hz + 10%
- Environment - 0 to 50°, 95% RH (Non-condensing), typical testing labs.
Battery bank installations are important & essential part of various power, communication, information technology & industrial set-ups. In order to ensure healthy performance of such installations, the batteries used need to be properly monitored. One of the quick check methods is to measure the battery voltage & conductance of individual cells of a battery string and to identify & eliminate weak battery cells and save battery string from further degradation.
SCOPE's BCT 1 is the comprehensive battery operated, portable, hand held Battery Conductance Tester suitable for all Lead Acid & Nickel Cadmium cells having cell voltage of 1.2V / 2V / 6V / 12V. This is all in one single unit that allows you to measure without taking the battery system OFF LINE.
Features
- Smart, rugged and portable hand held device.
- Suitable for batteries up to 6000 Ah.
- Tests all types of batteries having cell voltage of 1.2V / 2V / 6V / 12V. Option of self-defined voltage is also available.
- On line measurement- No need to disconnect cell / string from system.
- Simultaneously tests cell terminal voltage, internal conductance and relative percentage capacity of the cell.
- Built-in refrence value or selft defined value for comparison of test results with standart values.
- Low frequency testing effectively avoids interference from capacitive resistance of battery itself.
- Stable and accurate results in presence of high interference.
- Fast operation & quick stabilization. Auto saving of results.
- Colour touch screen display as well as operation through keypad.
- Large memory to store results of up-to 3000 cells.
- Auto-calibration of unit before testing.
- Over voltage protection & audio alarm.
- Analysis of results through PC Data Management Software including Histogram.
Specifications
Parameter | Range | Resolution | Accuracy |
Conductance (Siemence) | 100 to 19990Ω | 0.01mΩ | ±1.0% of reading ± 6 digit |
Voltage | 0 to 16V | 1mV | ±0.2% of reading ± 6 digit |
Measuring Cells Per String | Up to 254 | ||
Display | Colour TFT touch screen LCD, 320 x 240 pixel, 3.5" | ||
Memory | 3000 test results | ||
Power Supply | Li-ion battery | ||
Working Time | > 5 hours continuous | ||
Environment | 0°C to 50°C, up-to 95% RH (Non-condensing) | ||
Dimension (L x W x H) | 210 mm x 110 mm x 60 mm | ||
Weight | 2 kg (including accessories) |
These new CT/PT testers are based on low frequency and variable frequency methods which lead to the great reduction in weight and high knee point test range. With one button click, all test items of the current transformer test set, such as excitation, winding resistance, polarity, phase error, ratio, etc, can be performed automatically.
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
Features
- Test CT according to IEC60044-1/6
- Can test all types of CT, including bushing and GIS type CT
- One test can get all CT parameters
- Fast test time for excitation test
- 10kV knee point test: 50s
- 1kV knee point test: 15s
- Ratio check up to 30,000:1
- Knee point check up to 30,000V
- Lightweight, Automatic and Compact CT/PT tester with large LCD display, onboard memory and computer interface
- Principle based on variable frequency method which leads to high knee point test voltage range
- Testing CT Ratio by voltage method, having fast response time, high precision and reliability
- Embedded microprocessor digital platform without external PC, easy to operate and reduces test time
- With one click following test can be performed such as excitation, winding resistance, polarity, phase error, ratio, etc
- Name Plate Guessing facility
- Ratio error and phase error list automatically shown when the rated current is 1% to 300%.
- Inbuilt Demagnetization facility
- PT test functions are also in-built
- Test results can be saved to flash disk
- Optional Excel format report generation
- Large color LCD display
- Weight : 14kg
Specifications
Parameters | PCT200i |
Output Voltage range | 0 to 120V |
Output Current range | 0 to 5A rms (15A Peak) |
Output Power | 0.0001 to 500VA rms (1,500VA Peak) |
Ratio Test range | 30000:1 to 45000:5 |
Ratio Test Accuracy | 0.1% |
Max. Knee point voltage | 30,000V |
Burden test range | 0.5 to 200Ω |
Burden test accuracy | ± 0.1% ± 1mΩ |
Winding Resistance test range | 0.05 to 200Ω |
Winding Resistance test accuracy | ± 0.1% ± 1mΩ |
Display | 8.4 inch, Colour LCD |
Operating System | Windows |
Dimension (W x H x L) | 470 x 200 x 245mm |
Weight | 14Kg |