CFL SG 0810
Surge Generator is the backbone of underground cable fault locator test systems. Surge Generator is used with a Prelocator and SIM Filter for fault distance measurement and also used with Pin Pointer Set for pinpointing the exact fault spot.
SCOPE offers CFL SG 0810, Surge Generator with output of 8kV and 1000 Joules. It is ideal choice for fault location on all types of power cables from LV to MV. CFL SG series is equipped with different Protections, Interlocks and Auto-discharge facility to ensure user safety during operation. User friendly controls, adequate form factor, contact free HV terminations makes this CFL SG series most durable and best-designed sets in the segment
Features
- Compact, Lightweight, and housed in rugged aluminum case
- Ideal choice for fault location on all type of power cables
- Backbone of Cable Fault Locator System
- Generates short duration high voltage surge for fault break down
- Built-in Current Coupler to determine the fault distance in conjunction with Prelocator unit
- Repetitive surges applied for pinpointing the exact fault location in conjunction Pinpointing set
- Supports SIM/ARM/MIM method for locating High resistance and flashing faults along with Prelocator and SIM Filter from CFL Series
- Available with optional modes such as DC Hi-Pot, Burn Down and Sheath Fault Location Mode
- Multiple options in a single instrument to avoid carrying several heavy instruments to the site
- Easy setup and intelligent protections make high voltage testing safe & reliable
- Compatible with other models of SCOPE make CFL Series
Specifications
Parameter | CFL SG 0810 |
Output Voltage Ranges | 0 – 2kV / 4kV / 8kV selectable |
Output Energy | Max. 1000J in each voltage range |
Impulse Sequence (Surge Rate) |
Single Impulse (Manual) - 3 Sec / 6 Sec / 9 Sec or Single Impulse (Manual) - 2 Sec / 4 Sec / 8 Sec (Optional) |
Output Indication | Moving Coil Analog Meter for Output Voltage measurement |
Measurement Accuracy | ±5% of selected range |
Input Supply |
230V AC ± 10%, 50/60Hz ± 10%, Single Phase |
Cooling Type | Air Cooled |
Dimensions |
725 x 540 x 780mm |
Weight (without wheels and test leads) |
90kg approx. |
Environmental (Operation) |
0°C to 50°C, up to 95% RH (Non-Condensing) |
Environmental (Storage) |
-10°C to 55°C, up to 95% RH (Non-Condensing) |