SA 30i+

SA 30i+, the wireless Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.

The SA 30i+ can be pre-loaded with the LA identity details (LA Identification, Type, Serial Number,Location, Rated Voltage etc.) and tests conducted on the same ID of the arresters are saved under the same folder. Trend analysis software, SAData picks up this data and stores them in a similar fashion on a PC. This analysis software enables the user to take a decision to repair/replace the arresters considering safety limits.

SA 30i+ is designed to work under the hostile electrostatic noise found in live EHV switch yards upto 765 kV

 

Features

  • Safe Online measurement due to wireless CT and Field Probe
  • In built temperature measurement facility enables calculation of temperature corrected leakage currents.
  • Correction of results to rated voltage of LA to eliminate eff ect of change in system voltage.
  • Date and time stamp on test results Results are displayed on large font, Big, back-lit LCD, printed on in-built thermal printer and can be stored in memory of the instrument.
  • SA 30i+, CT unit and Field Probe unit are powered by easily available re-chargeable Lithium-ion batteries. It works for a day’s testing needs on a single charge
  • The SA 30i+ is a switchyard compatible instrument. This makes the instrument extremely convenient to use.
  • Built-in standard calibration source and self-calibration check facility
  • USB communication port to transfer data to PC and Windows based PC Downloading & Analysis Software.
  • Facility for testing of GIS LAs available optionally

Specifications

 Parameter  SA30i+
 Total Leakage Current Range  1 μA to 20 mA
 Resistive Leakage Current Range 1 μA to 20 mA 
Resolution   1 μA
 Accuracy Value ± 5% ± 1 μA 
 Inputs Wireless Clamp on CT and Wireless Field Probe optional external field PT Input (Voltage Peak method as per IEC 60099-5-A1 for GIS)
 Display 4 line x 20 character large backlit LCD with large font
 Compensation Automatic for System Harmonics, Temperature & System Voltage
 Temperature Sensor

Inbuilt Platinum Resistance Thermometer

Self-calibration Check Available
PC Connectivity USB Port (Standard), RS 232 & Ethernet (Optional)
Memory Storage capacity of 2000 results
Printer  58mm Inbuilt Thermal Printer
Power

Battery as well as Mains powered Main Unit

Battery powered CT and FP Units

Internal Battery

SA30i+ - 11.1 V / 4400mAh Internal Rechargeable battery,

CT Unit - 11.1 V / 2200mAh Rechargeable battery,

Field Probe Unit - 11.1 V / 2200mAh Rechargeable battery. 

8 hours Battery life with full charge

Mains Supply  88 to 264 VAC, 47 to 63 Hz, Single Phase
Battery Charger Inbuilt in Main Unit, Connection to CT and Field Probe Provided
 Dimension

 

SA30i+ - 350 x 295 x 150 mm,

CT Unit - 366 x 85 x 43 mm,

Field Probe Unit - 340 x 95 mm Cylindrical 

 Weight

 

SA30i+ - 5.0 Kg,

CT Unit - 0.7 Kg ,

Field Probe Unit - 1.2 Kg 

Environment 

-20°C to 55°C, up to 95% RH (non-condensing), Storage Temp - 0-70°C

Type Testing

As per IEC 60068 / IS 9000 for Dry Heat, Damp Heat, Change of Temperature, Bump, Vibration and Mechanical Shock. For EMI / EMC & Safety as per relevant IEC Standards

Video

 

Friday, 24 July 2020 07:10 Written by

SA 30i

SA 30i, the Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.

The SA 30i can be pre-loaded with the LA identity details (LA Identification, Type, Serial Number, Location, Rated Voltage etc.) and tests conducted on the same ID of the arresters are saved under the same folder. Trend analysis software, SAData picks up this data and stores them in a similar fashion on a PC. This analysis software enables the user to take a decision to repair/replace the arresters considering safety limits.

SA 30i is designed to work under the hostile electrostatic noise found in live EHV switch yards up to 765 kV

 

Features

  • An innovative design makes SA 30i simple, lightweight, portable, feature-rich.
  • Measures Total Leakage Current, 3rd Harmonic Resistive Leakage Current with System Harmonic compensation and Corrected Resistive Leakage Current.
  • In built temperature measurement facility enables calculation of temperature corrected leakage currents.
  • Correction of results to rated voltage of LA to eliminate effect of change in system voltage.
  • Date and time stamp on test results
  • Results are displayed on large font, Big, back-lit LCD, printed on in-built thermal printer and can be stored in memory of the instrument.
  • SA 30i is powered by easily available re-chargeable Lithium-ion batteries. It works for a day’s testing needs on a single charge
  • The SA 30i is a switchyard compatible instrument. This makes the instrument extremely convenient to use.
  • Built-in standard calibration source and self-calibration check facility
  • USB communication port to transfer data to PC and Windows based PC Downloading & Analysis Software.
  • Facility of extending CT & Field Probe signal to external oscilloscope.
  • Facility for testing of GIS LAs available optionally

Specifications

 Parameter  SA30i
 Total Leakage Current Range  100 μA to 10 mA
 Resistive Leakage Current Range 1 μA to 10 mA 
Resolution   1 μA
 Accuracy Value ± 5% ± 1 μA 
 Inputs External Clamp-on CT, Field Probe,Optional External PT input (110V AC)
 Display 4 line x 20 character large backlit LCD with large font
 Compensation Automatic for System Harmonics, Temperature & System Voltage
 Temperature Sensor

Inbuilt Platinum Resistance Thermometer

with measurement range of -20°C to 55°C

Self-calibration Check Available
PC Connectivity Through USB Port
Memory Storage capacity of 1000 results
Printer  58mm Inbuilt Thermal Printer

Internal Battery

SA30i - 11.1 V / 2200mAh Internal Rechargeable battery

Mains Supply  100-270V AC, 50 / 60Hz ± 10%, 1 Phase
 Dimension

SA30i - 415 x 330 x 200 mm

 Weight

SA30i - 7 Kg

Environment 

0°C to 55°C, up to 95% RH (non-condensing)

Type Testing

As per IEC 60068 / IS 9000 for Dry Heat, Damp Heat, Change of Temperature, Bump, Vibration and Mechanical Shock. For EMI / EMC & Safety as per relevant IEC Standards

Video

 

Friday, 24 July 2020 08:29 Written by

SA 10i

SA 10i the Leakage Current Meter from SCOPE T&M is a State of the Art, hand held, on-line test system for Residual Life Assessment of Surge Arresters. The instrument measures and directly displays the values of peak (Ipeak) and RMS (Irms) of total leakage current and calculates & displays resistive element of the total leakage current insurge arrestors connected in either 50Hz or 60Hz AC systems.

The SA 10i can be pre-loaded with the LA identity (LA Identification, Type, Serial Number, Location, Rated Voltage etc.) and tests conducted on the same ID of the Arresters are saved under its own library created. Trend analysis software; SAData picks up this data and files them in a similar fashion on a PC. This analysis software enables the user to take a decision to repair/replace the arresters considering safety limits.

The device has an in-built temperature sensor to measure ambient temperature and displays it. Also as system voltage and ambient temperature keeps on varying; SA 10i applies correction factors for system voltage correction and also temperature correction to get corrected resistive leakage current.

SA 10i is designed and manufactured by SCOPE T&M Pvt. Ltd., India, for reliable operation in high-noise live HV switchyard environments.

Features

  • This hand held SA 10i is CE Certified, simple, lightweight, portable, feature-rich and affordable.
  • Measures 3rd harmonic resistive current, and the peak and RMS of total leakage current of surge arrestors connected in either 50Hz or 60Hz AC systems
  • In built temperature measurement facility enables calculation of temperature compensated leakage currents
  • Correction of results to rated voltage of LA to eliminate effect of change in system voltage.
  • Up to 1000 test records with date and time stamp on test results are stored in the in-built memory
  • The SA 10i is powered by easily available re-chargeable Lithium-ion batteries. It works for a day’s testing needs on a single charge. It also displays the battery status, like % of charge and low battery indication.
  • The SA 10i is a switch-yard compatible instrument. This makes the instrument extremely convenient to use.
  • USB communication port to transfer data to PC and Windows based PC Downloading & Analysis Software.
  • Data Management, Analysis and Trending through SA Data software

Specifications

 

Parameter SA 10i
Total Leakage Current Range (Peak & RMS)   100 μA to 10mA
 3rd Harmonic Resistive Leakage Current Range (Peak & RMS)   1 μA to 10mA
Resolution   1 μA
Accuracy  Value ± 5%
 Inputs External Clamp-on CT
 Display 2 line x 16 character back-lit LCD
 Compensation Automatic for Noise & Temperature
 Temperature Sensor

Inbuilt silicon thermometer

Temperature Range 

0 to 99°C

PC Connectivity Through USB Port
Memory Storage capacity of 1000 results
Power  Supply  7.4V / 1150mAh, Internal rechargeable battery
Battery Charging 100-270V AC, 50 / 60Hz ± 10%, 1 Phase
 Dimension

 190 x 125 x 50 mm

 Weight

 1.5 Kg